Maintenance Of Cable Winch
Leave a message
In our real life, when we see the cable winch, we should think of what it is doing. You should know if it is not used properly, will give us the middle of what kind of work harm, and there is no danger to us and so on. These as common sense should be everyone knows! However, Cable Winch I believe that many people do not know when using the cable winch, you should pay attention to what it is. Let me tell you the following.
And we know that the cable winch began to work, we must pay attention to the two brakes at the same time can not brake the action, because you may make this action its motor burned. And may cause a fire to occur. While the use of cable winch also pay attention to it when using a temperature! The normal use of our winch temperature is the drum brake belt and the bearing temperature can not exceed 70 degrees Celsius. Cable Winch If the process of using the middle of the temperature found that the temperature is not normal, then we must stop to see where the problem is a check!
Cable winch using the inverter is a four-quadrant inverter, it has a feedback unit, when the cable winch in the decentralized time, the inverter is in the feedback of this thing mode, that is, the motor in the power state to the power grid to feedback energy, this time Will also produce a large current in the DC screening device performance is not very good environment, this current is enough to burn the components on the DC cover. Thus affecting the normal thing of the winch. If the test or other events necessary power outage, you must stop the operation of the rectifier feedback unit, Cable Winch and then stop the reactor, to stop the electric control box, the last to stop the power supply switching power supply, power supply, power supply, power supply, power supply, The It is forbidden to appear directly in the power supply switch. Enhanced second-class winch room power supply system inspection, is strictly prohibited power supply system discharge environment. Such as the emergence of power supply system hidden danger, must be immediately checked to clear the hidden dangers.
And the cable winch is also a car, so it can not be overloaded work. So the damage to the winch is very large! And before you use the winch should also be empty car running to ensure that it can work properly, Cable Winch and in the usual time to the cable winch for routine maintenance to ensure that the winch will not rust! And when the placement time is relatively long, we must carry out the appropriate maintenance of the winch! In our lives, there are many precautions about using the cable winch, and in order to protect our lives, we need to understand it further.